Projet

Général

Profil

EdgeOS » Historique » Version 1

Version 1/31 - Suivant » - Version actuelle
Laurent GUERBY, 23/10/2016 18:47


EdgeOS

Commandes

show interfaces status all
Port       Name                          State   Mode        Status      Type                Status
---------  ----------------------------  ------  ----------  ----------  ------------------  ------------
0/1                                      Down    Auto                    Unknown             Inactive
0/2                                      Down    Auto                    Unknown             Inactive
0/3                                      Up      Auto        100 Full    Unknown             Active
...

(UBNT EdgeSwitch) #show interfaces switchport

Port: 0/1
VLAN Membership Mode: General
Access Mode VLAN: 1 (default)
General Mode PVID: 3131
General Mode Ingress Filtering: Disabled
General Mode Acceptable Frame Type: Admit all
General Mode Dynamically Added VLANs:
General Mode Untagged VLANs: 3131
General Mode Tagged VLANs: 3199
General Mode Forbidden VLANs: 1,20,128,376,3132,3166,3175
Trunking Mode Native VLAN: 1 (default)
Trunking Mode Native VLAN tagging: Disable
Trunking Mode VLANs Enabled: All
Protected Port: False

Port: 0/2
...
(UBNT EdgeSwitch) #show fiber-ports optics-info all

                         Link Link                                 Nominal
                       Length Length                                   Bit
                         50um 62.5um                                  Rate
Port     Vendor Name      [m] [m]  Serial Number    Part Number     [Mbps] Rev  Compliance
-------- ---------------- --- ---- ---------------- ---------------- ----- ---- ----------------
0/49     OEM              0   0    SG35E40803862    SFP+10GSMD3120LC 10300 A    10GBase-LR
0/50     OPTIC            0   0    STC03051500015   OPTICSFP+10GCP3M 10300 A0   DAC

(UBNT EdgeSwitch) #show fiber-ports optics all     

                                    Output    Input
Port      Temp  Voltage  Current     Power    Power   TX     LOS
           [C]   [Volt]     [mA]     [dBm]    [dBm]   Fault
--------  ----  -------  -------   -------  -------   -----  ---
0/49      45.2    3.332     31.5    -3.079   -3.223   No     No
0/50       N/A      N/A      N/A       N/A      N/A   N/A    N/A

 Temp - Internally measured transceiver temperatures.
 Voltage - Internally measured supply voltage.
 Current - Measured TX bias current.
 Output Power - Measured optical output power relative to 1mW.
 Input Power - Measured optical power received relative to 1mW.
 TX Fault - Transmitter fault.
 LOS - Loss of signal.
</pre