EdgeOS¶
ES-48-Lite EdgeOS 1.7.3
Documentation¶
https://dl.ubnt.com/guides/edgemax/EdgeOS_UG.pdf
https://dl.ubnt.com/guides/edgemax/EdgeSwitch_CLI_Command_Reference_UG.pdf
Commandes¶
(UBNT EdgeSwitch) #show mac-addr-table VLAN ID MAC Address Interface IfIndex Status ------- ------------------ --------------------- ------- ------------ 1 00:01:E8:8B:4F:CF 0/49 49 Learned 1 00:08:7C:3C:29:03 0/49 49 Learned 128 9C:B6:54:06:7E:56 0/5 5 Learned ...
show interfaces status all Port Name State Mode Status Type Status --------- ---------------------------- ------ ---------- ---------- ------------------ ------------ 0/1 Down Auto Unknown Inactive 0/2 Down Auto Unknown Inactive 0/3 Up Auto 100 Full Unknown Active ... (UBNT EdgeSwitch) #show interfaces switchport Port: 0/1 VLAN Membership Mode: General Access Mode VLAN: 1 (default) General Mode PVID: 3131 General Mode Ingress Filtering: Disabled General Mode Acceptable Frame Type: Admit all General Mode Dynamically Added VLANs: General Mode Untagged VLANs: 3131 General Mode Tagged VLANs: 3199 General Mode Forbidden VLANs: 1,20,128,376,3132,3166,3175 Trunking Mode Native VLAN: 1 (default) Trunking Mode Native VLAN tagging: Disable Trunking Mode VLANs Enabled: All Protected Port: False Port: 0/2 ...
(UBNT EdgeSwitch) #show fiber-ports optics-info all Link Link Nominal Length Length Bit 50um 62.5um Rate Port Vendor Name [m] [m] Serial Number Part Number [Mbps] Rev Compliance -------- ---------------- --- ---- ---------------- ---------------- ----- ---- ---------------- 0/49 OEM 0 0 SG35E40803862 SFP+10GSMD3120LC 10300 A 10GBase-LR 0/50 OPTIC 0 0 STC03051500015 OPTICSFP+10GCP3M 10300 A0 DAC (UBNT EdgeSwitch) #show fiber-ports optics all Output Input Port Temp Voltage Current Power Power TX LOS [C] [Volt] [mA] [dBm] [dBm] Fault -------- ---- ------- ------- ------- ------- ----- --- 0/49 45.2 3.332 31.5 -3.079 -3.223 No No 0/50 N/A N/A N/A N/A N/A N/A N/A Temp - Internally measured transceiver temperatures. Voltage - Internally measured supply voltage. Current - Measured TX bias current. Output Power - Measured optical output power relative to 1mW. Input Power - Measured optical power received relative to 1mW. TX Fault - Transmitter fault. LOS - Loss of signal.
Allumer un port et remplir sa description¶
(UBNT EdgeSwitch) #conf (UBNT EdgeSwitch) (Config)#interface 0/33 (UBNT EdgeSwitch) (Interface 0/33)#no shutdown (UBNT EdgeSwitch) (Interface 0/33)#description gentilserveur (UBNT EdgeSwitch) (Interface 0/33)#exit (UBNT EdgeSwitch) #write memory This operation may take a few minutes. Management interfaces will not be available during this time. Are you sure you want to save? (y/n) y Config file 'startup-config' created successfully . Configuration Saved!
(UBNT EdgeSwitch) #write memory This operation may take a few minutes. Management interfaces will not be available during this time. Are you sure you want to save? (y/n) y Config file 'startup-config' created successfully . Configuration Saved!
(UBNT EdgeSwitch) #conf (UBNT EdgeSwitch) (Config)#interface 0/35 (UBNT EdgeSwitch) (Interface 0/35)#shut (UBNT EdgeSwitch) (Interface 0/35)#do write memory This operation may take a few minutes. Management interfaces will not be available during this time. Are you sure you want to save? (y/n) y Config file 'startup-config' created successfully . Configuration Saved! (UBNT EdgeSwitch) (Interface 0/35)#
(UBNT EdgeSwitch) (Config)#interface 0/12-0/15 (UBNT EdgeSwitch) (Interface 0/12-0/15)#shut
(s58) #copy nvram:startup-config tftp://192.168.3.19/s58 Mode........................................... TFTP Set Server IP.................................. 192.168.3.19 Path........................................... ./ Filename....................................... s58 Data Type...................................... Text Configuration Management access will be blocked for the duration of the transfer Are you sure you want to start? (y/n) y File transfer operation completed successfully. (s58) #
Exemple¶
À titre d'exemple, activons le port 1 du switch s54 localisé à Picto afin d'y connecter un dispositif. On peut se connecter au switch de diverses façons, cependant à distance, on peut se connecter d'abord sur nagios.tetaneutral.net et, de là, atteindre s54. Ceci nécessite d'avoir sa clef sur nagios afin de permettre la connexion ssh. ssh -lroot -p2222 nagios.tetaneutral.net Connexion à s54 passwd: ubnt ssh ubnt@s54 Après connexion au switch, on passe en root pw: ubnt enable On passe ensuite en mode config conf Pour la config du port 1 interface 0/1