Projet

Général

Profil

EdgeOS » Historique » Version 21

« Précédent - Version 21/31 (diff) - Suivant » - Version actuelle
Christian Frabel, 04/01/2023 17:02


EdgeOS

ES-48-Lite EdgeOS 1.7.3

Documentation

https://dl.ubnt.com/guides/edgemax/EdgeOS_UG.pdf
https://dl.ubnt.com/guides/edgemax/EdgeSwitch_CLI_Command_Reference_UG.pdf

Commandes

(UBNT EdgeSwitch) #show mac-addr-table 

VLAN ID  MAC Address         Interface              IfIndex  Status
-------  ------------------  ---------------------  -------  ------------
1        00:01:E8:8B:4F:CF   0/49                   49       Learned
1        00:08:7C:3C:29:03   0/49                   49       Learned
128      9C:B6:54:06:7E:56   0/5                    5        Learned
...
show interfaces status all
Port       Name                          State   Mode        Status      Type                Status
---------  ----------------------------  ------  ----------  ----------  ------------------  ------------
0/1                                      Down    Auto                    Unknown             Inactive
0/2                                      Down    Auto                    Unknown             Inactive
0/3                                      Up      Auto        100 Full    Unknown             Active
...

(UBNT EdgeSwitch) #show interfaces switchport

Port: 0/1
VLAN Membership Mode: General
Access Mode VLAN: 1 (default)
General Mode PVID: 3131
General Mode Ingress Filtering: Disabled
General Mode Acceptable Frame Type: Admit all
General Mode Dynamically Added VLANs:
General Mode Untagged VLANs: 3131
General Mode Tagged VLANs: 3199
General Mode Forbidden VLANs: 1,20,128,376,3132,3166,3175
Trunking Mode Native VLAN: 1 (default)
Trunking Mode Native VLAN tagging: Disable
Trunking Mode VLANs Enabled: All
Protected Port: False

Port: 0/2
...
(UBNT EdgeSwitch) #show fiber-ports optics-info all

                         Link Link                                 Nominal
                       Length Length                                   Bit
                         50um 62.5um                                  Rate
Port     Vendor Name      [m] [m]  Serial Number    Part Number     [Mbps] Rev  Compliance
-------- ---------------- --- ---- ---------------- ---------------- ----- ---- ----------------
0/49     OEM              0   0    SG35E40803862    SFP+10GSMD3120LC 10300 A    10GBase-LR
0/50     OPTIC            0   0    STC03051500015   OPTICSFP+10GCP3M 10300 A0   DAC

(UBNT EdgeSwitch) #show fiber-ports optics all     

                                    Output    Input
Port      Temp  Voltage  Current     Power    Power   TX     LOS
           [C]   [Volt]     [mA]     [dBm]    [dBm]   Fault
--------  ----  -------  -------   -------  -------   -----  ---
0/49      45.2    3.332     31.5    -3.079   -3.223   No     No
0/50       N/A      N/A      N/A       N/A      N/A   N/A    N/A

 Temp - Internally measured transceiver temperatures.
 Voltage - Internally measured supply voltage.
 Current - Measured TX bias current.
 Output Power - Measured optical output power relative to 1mW.
 Input Power - Measured optical power received relative to 1mW.
 TX Fault - Transmitter fault.
 LOS - Loss of signal.

Allumer un port et remplir sa description

(UBNT EdgeSwitch) #conf
(UBNT EdgeSwitch) (Config)#interface 0/33

(UBNT EdgeSwitch) (Interface 0/33)#no shutdown

(UBNT EdgeSwitch) (Interface 0/33)#description gentilserveur

(UBNT EdgeSwitch) (Interface 0/33)#exit

(UBNT EdgeSwitch) #write memory 
This operation may take a few minutes.
Management interfaces will not be available during this time.
Are you sure you want to save? (y/n) y

Config file 'startup-config' created successfully .

Configuration Saved!

(UBNT EdgeSwitch) #write memory         

This operation may take a few minutes.
Management interfaces will not be available during this time.

Are you sure you want to save? (y/n) y

Config file 'startup-config' created successfully .

Configuration Saved!
(UBNT EdgeSwitch) #conf

(UBNT EdgeSwitch) (Config)#interface 0/35

(UBNT EdgeSwitch) (Interface 0/35)#shut

(UBNT EdgeSwitch) (Interface 0/35)#do write memory

This operation may take a few minutes.
Management interfaces will not be available during this time.

Are you sure you want to save? (y/n) y

Config file 'startup-config' created successfully .

Configuration Saved!

(UBNT EdgeSwitch) (Interface 0/35)#

(UBNT EdgeSwitch) (Config)#interface 0/12-0/15

(UBNT EdgeSwitch) (Interface 0/12-0/15)#shut
(s58) #copy nvram:startup-config tftp://192.168.3.19/s58

Mode........................................... TFTP  
Set Server IP.................................. 192.168.3.19
Path........................................... ./
Filename....................................... s58
Data Type...................................... Text Configuration

Management access will be blocked for the duration of the transfer
Are you sure you want to start? (y/n) y

File transfer operation completed successfully.

(s58) #

Exemple

À titre d'exemple, activons le port 1 du switch s54 localisé à Picto afin d'y connecter un dispositif.
On peut se connecter au switch de diverses façons, cependant à distance, on peut se connecter d'abord sur nagios.tetaneutral.net et, de là, atteindre s54.
Ceci nécessite d'avoir sa clef sur nagios afin de permettre la connexion ssh.

*ssh -lroot -p2222 nagios.tetaneutral.net*
Connexion à s54 passwd: ubnt
ssh ubnt@s54
Après connexion au switch, on passe en root pw: ubnt
enable
On passe ensuite en mode config
conf
Pour la config du port 1
interface 0/1
On active le port
no shut 
On revient en mode config général
exit
Puis on sort du mode config
exit
Il faut encore sauver la config dans une mémoire permanente
write mem

??La configuration est terminée??